Skip to content

Ratek RC4 Re-Circulating Cooler with Tank

$8,580.00

Notify me when back in stock

Product Overview
The RC4 Refrigerated waterbath when used with an optional immersion heater circulator will provide accurate temperature controlled water at or below ambient temperatures. The waterbath has a capacity of approximately 12 litres. A built in heavy duty recirculating pump provides closed loop circulation at the rate of 7 litres per minute, and can offer a reliable and preferable alternative to the use of mains water for cooling Heat exchangers, Electrophoresis baths, Condensers, etc.

To avoid accidental damage to the heat exchanger components the RC4 cooling is set to turn of at 4°c, however it can be factory set to have a minimum temperature of -10°C if required. Suitable additives would need to be added to the water for the -10°c version to avoid damage to the system.

Polished grade 304 stainless steel is used for the tank, and surround, and the main case is constructed from a heavy duty plastic. Heat exchanger components are manufactured from copper. Only environmentally friendly R134a refrigerant is used in Ratek coolers.

  • 580 Watts Cooling Capacity
  • 7 L/min Pump Flow Rate
  • Quiet Operation
  • Accessible Cold Reservoir Tank
  • -10°C to +30°C Operating Range
  • Extremely Reliable

Specifications

  • Cooling Capacity: Average 580 Watts between 30°C and 5°C
  • Reservoir Dimensions: L275 × W200 × D200mm
  • Filling Capacity: 12 litres including heat exchanger
  • Refrigerant Type: R134a
  • Pump Flow Rate: 7 litres per minute at zero head, max pressure 3.2 psi
  • Condenser: ½ hp air cooled hermetic condensing unit
  • Operating Range: -10°C to +30°C (using suitable additives)
  • Thermostat: Adjustable low-temp safety cut-off (factory default is +4°C)
    • For temperature control, the TH8000 is required
  • Power Input: 240VAC/690W
  • Overall Dimensions: L480 × W340 × D510mm
  • Nett Weight: 27 kg

 

Product Overview
The RC4 Refrigerated waterbath when used with an optional immersion heater circulator will provide accurate temperature controlled water at or below ambient temperatures. The waterbath has a capacity of approximately 12 litres. A built in heavy duty recirculating pump provides closed loop circulation at the rate of 7 litres per minute, and can offer a reliable and preferable alternative to the use of mains water for cooling Heat exchangers, Electrophoresis baths, Condensers, etc.

To avoid accidental damage to the heat exchanger components the RC4 cooling is set to turn of at 4°c, however it can be factory set to have a minimum temperature of -10°C if required. Suitable additives would need to be added to the water for the -10°c version to avoid damage to the system.

Polished grade 304 stainless steel is used for the tank, and surround, and the main case is constructed from a heavy duty plastic. Heat exchanger components are manufactured from copper. Only environmentally friendly R134a refrigerant is used in Ratek coolers.

  • 580 Watts Cooling Capacity
  • 7 L/min Pump Flow Rate
  • Quiet Operation
  • Accessible Cold Reservoir Tank
  • -10°C to +30°C Operating Range
  • Extremely Reliable

Specifications

  • Cooling Capacity: Average 580 Watts between 30°C and 5°C
  • Reservoir Dimensions: L275 × W200 × D200mm
  • Filling Capacity: 12 litres including heat exchanger
  • Refrigerant Type: R134a
  • Pump Flow Rate: 7 litres per minute at zero head, max pressure 3.2 psi
  • Condenser: ½ hp air cooled hermetic condensing unit
  • Operating Range: -10°C to +30°C (using suitable additives)
  • Thermostat: Adjustable low-temp safety cut-off (factory default is +4°C)
    • For temperature control, the TH8000 is required
  • Power Input: 240VAC/690W
  • Overall Dimensions: L480 × W340 × D510mm
  • Nett Weight: 27 kg

 

FREE ship[ping on all A&D Weighing products.

Please allow 1-3 business days for order processing.                                                                                                                                                                                                          Please allow up to 7 business days for delivery to capital cities.                                                                                                                                                                                          Please allow up to 14 days for delivery to all other places.

Back Orders: Some products may be out of stock when ordering. If your chosen product is on back order, you will be contacted before your order is processed. You will be informed of an estimated dispatch time period and at that point, your decision to move ahead with the order will be yours to make.

Lab Devices Australia delivery via FedEx on all Ratek products.

Cancellation: Cancellation of order can only be done if the product has not left the warehouse for shipping. If the product is already in transit upon cancellation request, normal unopened return policy will apply. This means that the product will have to be return unopened with return shipping covered by the customer.

Unopened Returns: There is a 30 day hassle free return on unopened products from date of purchase. The package must NOT be opened and MUST be in a resellable condition. So, this means the package that the product has come in must not be opened at all.

Return shipping costs MUST be covered and organised by the customer unless the product is damaged or faulty. Once product has been returned in a resellable condition and inspected, a refund will be processed.

We DO NOT accept returns on products once packaging has been opened, unless the product is proven to be damaged or faulty.

No returns on opened products (unless proven to be damaged or faulty).

No returns on unopened products after 30 Days.

Please contact support@labdevicesaustralia.com.au for any inquires.

Damaged Product During Transit: In regards to damaged products in transit; photographs must be taken of damage done to product. Please call 1300 812 450 immediately to report the situation. Notice of damage and photographs are to be immediately emailed to support@labdevicesaustralia.com.au within 24 Hours of receiving delivery. The customer may also call us at 1300 812 450 whilst the delivery is taking place if the damage is clearly obvious. Upon examination of photographs, a decision will be made as to what action will be taken by Lab Devices Australia. If the product is proven to be damaged during transit, a return/refund or return/replacement will be arranged with shipping provided by transit company. If the packing is damaged but the product is undamaged, then there will be no action taken by Lab Devices Australia.

Faulty Product: If the product is faulty, please contact support@labdevicesaustralia.com.au immediately so an arrangement can be made for a return/refund or return/replacement, under specified warranty conditions of the faulty product.

For any warranty claims and inquires, please contact support@labdevicesaustralia.com.au or call us at 1300 812 450. You will then be directed with the appropriate course of action to take.

Ratek products (excluding spare parts) are covered by a 3 year parts and 12 months labour return-to-base warranty effective from the date of purchase. Our products are manufactured in Melbourne, Australia. This warranty covers the repair or replacement of any parts or components found to be defective, subject to the service options listed below. The warranty is a return-to-base warranty, meaning any product must be returned to Ratek Instruments or an authorised Ratek agent for service at the discretion of Ratek Instruments. Where practical an on-site repair may be carried out at the discretion of Ratek Instruments.

This warranty excludes any defect resulting from misuse, neglect, accidental damage, improper voltage, operation of the product outside the acceptable operating conditions as indicated in the products operating instructions or any alteration which affects the performance of the equipment. It does not extend to any costs associated with delivery of the product to or from Ratek Instruments or an authorised Ratek agent, damage, or loss incurred during transport. This warranty is in addition to any Statutory regulations and provisions implied by the Trade Practices Act and any relevant State or Federal Government obligations, applicable only when purchased within Australia. The product may be replaced within the warranty period at the discretion of Ratek Instruments, however repair will be the normal course of action.

For a period of 3 years from date of purchase, replacement parts will be supplied at no charge and the original components returned to the repairer. These replacement parts may be installed by an approved service agent with prior written agreement from Ratek Instruments.

For a period of 12 months from date of purchase, service labour and repairs will be carried out at no charge by an approved repairer or Ratek Instruments at the discretion of Ratek Instruments. The limit of liability shall extend to the repair of the product only, all other compensation claims are excluded from this guarantee.

The warranty does not extend to claims of suitability where the product does not deliver the intended function or fails to operate. No claims of suitability are made in relation to the product by Ratek Instruments. Any claim of suitability lies with the operator. The product is used at the risk of the operator. Any loss or damage caused to any item used with the product including but not limited to biological samples, tubes, racks, accessories, flasks, containers or the contents of such containers caused by the malfunction of the product or the failure of the product to function is not covered by this warranty. Proof of purchase is required for all warranty repairs.

Inspection Charges
For products returned outside the warranty period a standard inspection fee may be charged.

All Other Returns
If you have received a product in error or have a query regarding an item you have received, please contact Lab Devices Australia on 1300 812 450 or email support@labdevicesaustralia.com.au
.

Click below to view the following PDFs.

RC4 Re-Circulating Cooler - Brochure PDFRC4 Re-Circulating Cooler - Brochure

Chiller Options - Brochure PDFChiller Options - Brochure

We get it. You've got a lot of choice when it comes to online retailers.
Here's why we think you should shop with us at Lab Devices Australia.

  • Free Shipping Australia wide. No extra charges. Ever.
  • Price Match Guarantee. Best prices online guaranteed.
  • 30 Day Easy Returns. Not happy with your product, we'll take it back no questions asked.
  • Great Service. We pride ourselves on the best service, anywhere.
  • Your Satisfaction Guaranteed. We handpick our products for quality, we know you'll love them. But if there is ever something wrong, we'll fix it.