Skip to content

A&D Weighing AD-4212A-PT & FX-300i-PT Pipette Accuracy Testers

$11,800.00
Model No. (Cap. x Res.)

Notify me when back in stock

AD-4212A-PT & FX-300i-PT Pipette Accuracy Tester Product Description

A complete test and reporting system for pipette accuracy based on the gravimetric method and complying with ISO Standard 8655. The Pipette Accuracy Tester includes an analytical or precision weighing system with extensive reporting software.

AD-4212A-PT & FX-300i-PT Pipette Accuracy Tester Features

  • Complies with ISO 8655 for Piston Operated Volumetric Apparatus.
  • Uses the Gravimetric Method of determining volume by converting mass measurement.
  • 3 Models cover a wide range of pipette volumes from 20 microlitres upwards.
  • Complete Testing System is supplied in aluminium transportation case.
  • WinCT Pipette Software designed to comply with all requirements of ISO8655.
  • High Grade Calibration Mass supplied as standard.
  • 30 ml and 5 ml Sample Cups to receive dispensed samples.
  • Evaporation Trap to ensure maximum recorded accuracy of dispensed samples.
  • High Grade Thermometer supplied as standard to ensure accurate recording of sample temperature.
  • Acceptance Tolerances can be manually overwritten to suit each locations test requirements.

AD-1690 Pipette Leak Tester Product Description

The AD-1690 Pipette Leak Tester instantly identifies any compromise in the pressure integrity of small pumps, piping, storage containers and especially micropipettes. Tests devise to 50ml capacity.

AD-1690 Pipette Leak Tester Features

  • Quick, reliable testing of less than 5 seconds.
  • Leak detection by depressurization ensuring no dust enters the object being measured.
  • Replaceable air filter to protect the AD-1690 from dust when it intakes air.
  • RS-232C interface to output data to a PC or an A&D peripheral device.
  • Five years warranty.

AD-4212A-PT & FX-300i-PT Pipette Accuracy Tester Product Description

A complete test and reporting system for pipette accuracy based on the gravimetric method and complying with ISO Standard 8655. The Pipette Accuracy Tester includes an analytical or precision weighing system with extensive reporting software.

AD-4212A-PT & FX-300i-PT Pipette Accuracy Tester Features

  • Complies with ISO 8655 for Piston Operated Volumetric Apparatus.
  • Uses the Gravimetric Method of determining volume by converting mass measurement.
  • 3 Models cover a wide range of pipette volumes from 20 microlitres upwards.
  • Complete Testing System is supplied in aluminium transportation case.
  • WinCT Pipette Software designed to comply with all requirements of ISO8655.
  • High Grade Calibration Mass supplied as standard.
  • 30 ml and 5 ml Sample Cups to receive dispensed samples.
  • Evaporation Trap to ensure maximum recorded accuracy of dispensed samples.
  • High Grade Thermometer supplied as standard to ensure accurate recording of sample temperature.
  • Acceptance Tolerances can be manually overwritten to suit each locations test requirements.

AD-1690 Pipette Leak Tester Product Description

The AD-1690 Pipette Leak Tester instantly identifies any compromise in the pressure integrity of small pumps, piping, storage containers and especially micropipettes. Tests devise to 50ml capacity.

AD-1690 Pipette Leak Tester Features

  • Quick, reliable testing of less than 5 seconds.
  • Leak detection by depressurization ensuring no dust enters the object being measured.
  • Replaceable air filter to protect the AD-1690 from dust when it intakes air.
  • RS-232C interface to output data to a PC or an A&D peripheral device.
  • Five years warranty.